Circuit Breaker for Transformer Protection, S2, 49...59 A
Circuit breaker size S2 for transformer protection A-trip 49-59 A N-trip 1040 A screw terminals standard breaking capacity. Standard breaking capacity 3RV2431-4XA10
Delivery time on requestk
Circuit Breaker for Transformer Protection S00, 0.7...1 A
Circuit breaker, size S00, for transformer protection; A-trip 0.7...1 A, N-trip 21 A; screw terminals; standard breaking capacity. Standard breaking capacity 3RV2411-0JA10
Available immediately
Circuit breaker for the transformer protection S00, 10–16 A
Circuit breaker size S00 for transformer protection A-trip 10...16 A N-trip 286 A screw terminals standard breaking capacity. Standard breaking capacity 3RV2411-4AA10
Available immediately
Circuit Breaker for Transformer Protection S00, 7...10 A
Circuit breaker size S00 for transformer protection A-trip 7...10 A N-trip 208 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2411-1JA10
Available immediately
Circuit Breaker for Transformer Protection, S00, 0.55...0.8 A
Circuit breaker size S00 for transformer protection A-trip 0.55...0.8 A N-trip 16 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2411-0HA10
Available immediately
Circuit Breaker for Transformer Protection S00, 0.45...0.63 A
Circuit breaker size S00 for transformer protection A-trip 0.45...0.63 A N-trip 13 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2411-0GA10
Available immediately
Circuit Breaker for Transformer Protection S00, 0.35...0.5 A
Circuit breaker size S00 for transformer protection A-trip 0.35...0.5 A N-trip 10 A screw terminals standard breaking capacity. Standard breaking capacity 3RV2411-0FA10
Delivery time on requestk
Circuit Breaker for Transformer Protection S00, 5.5...8 A
Circuit breaker size S00 for transformer protection A-trip 5.5...8 A N-trip 163 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2411-1HA10
Available immediately
Circuit Breaker for Transformer Protection S00, 1.4...2 A
Circuit breaker size S00 for transformer protection A-trip mechanism 1.4...2 A N-trip mechanism 42 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2411-1BA10
Available immediately
Circuit breaker for transformer protection, size S0, 18...25 A
Circuit breaker, size S0, for transformer protection; A-trip 18...25 A, N-trip 400 A; screw terminals; standard breaking capacity with transverse auxiliary switch 1S+1Ö. Standard switching capacity: 1NO, 1NC, 3RV2421-4DA15
Delivery time on requestk
Circuit Breaker for Transformer Protection S00, 0.9...1.25 A
Circuit breaker size S00 for transformer protection A-trip 0.9...1.25 A N-trip 26 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2411-0KA10
Available immediately
Circuit Breaker for Transformer Protection S00, 1.8...2.5 A
Circuit breaker size S00 for transformer protection A-trip 1.8...2.5 A N-trip 52 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2411-1CA10
Available immediately
Circuit breaker for transformer protection S3, 57...75 A
Circuit breaker size S3 for motor protection, CLASS 20 A-trip unit 57...75 A N-trip unit 975 A screw terminal increased breaking capacity 100 kA. increased breaking capacity 100 kA 3RV2042-4KB10
Delivery time on requestk
Circuit Breaker for Transformer Protection S00, 2.2...3.2 A
Circuit breaker size S00 for transformer protection A-trip 2.2...3.2 A N-trip 65 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2411-1DA10
Available immediately
Circuit Breaker for Transformer Protection S00, 3.5...5 A
Circuit breaker, size S00, for transformer protection; A-trip 3.5...5 A, N-trip 104 A; screw terminals; standard breaking capacity. Standard breaking capacity 3RV2411-1FA10
Available immediately
Circuit Breaker for Transformer Protection S00, 9...12.5 A
Circuit breaker size S00 for transformer protection A-trip 9...12.5 A N-trip 260 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2411-1KA10
Available immediately
Circuit breaker for transformer protection S00, 4.5...6.3 A
Circuit breaker size S00 for transformer protection A-trip 4.5...6.3 A N-trip 130 A screw terminals standard breaking capacity. Standard breaking capacity 3RV2411-1GA10
Available immediately
Circuit Breaker for Transformer Protection, S00, 1.1...1.6 A
Circuit breaker size S00 for transformer protection A-trip 1.1...1.6 A N-trip 33 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2411-1AA10
Delivery time on requestk
Circuit breaker for transformer protection, size S0, 16...22 A
Circuit breaker size S0 for transformer protection A-trip 16...22 A N-trip 364 A screw terminal standard breaking capacity. Standard breaking capacity 3RV2421-4CA10
Available immediately
Circuit Breaker for Transformer Protection, S0, 10...16 A
Circuit breaker, size S0, for transformer protection; A-trip 10...16 A, N-trip 286 A; screw terminals; standard breaking capacity with transverse auxiliary contacts 1S+1Ö. Standard breaking capacity 1NO 1NC 3RV2421-4AA15
Delivery time on requestk
Circuit Breaker for Transformer Protection S00, 0.28...0.4 A
Circuit breaker, size S00, for transformer protection; A-trip 0.28...0.4 A, N-trip 8.2 A; screw terminals; standard breaking capacity. Standard breaking capacity 3RV2411-0EA10
Available immediately
Circuit Breaker for Transformer Protection S00, 0.22...0.32 A
Circuit breaker, size S00, for transformer protection; A-trip 0.22...0.32 A, N-trip 6.5 A; screw terminals; standard breaking capacity. Standard breaking capacity 3RV2411-0DA10
Available immediately
Circuit Breaker for Transformer Protection, S00, 2.8...4 A
Circuit breaker, size S00, for transformer protection; A-trip 2.8...4 A, N-trip 82 A; screw terminals; standard breaking capacity. Standard breaking capacity 3RV2411-1EA10
Available immediately
Circuit breaker for transformer protection, size S0, 18...25 A
Circuit breaker, size S0, for transformer protection; A-trip 18...25 A, N-trip 400 A; spring-loaded connection; standard breaking capacity. Standard breaking capacity 3RV2421-4DA20
Delivery time on requestk