Filter products
- News
-
Manufacturers
- ABB
- AEC
- AQ Riedel Trafobau GmbH
- Carlo Gavazzi
- Comat Releco
- E.T.A.
- Eaton
- Fibox
-
Finder
- Electronic Solid-State Relays (SSR)
- Electronic Active Current Meters
- Home and Building Automation
- Industrial and PCB Relays (EMR/SSR)
- Industrial Contactors
- Installation Contactors
- Coupling Relays (EMR/SSR)
- Relays with positively driven contacts
- Switching Power Supplies
- Control Cabinet Components
- Pulse Switches
- Surge Protection Devices (SPDs)
- Monitoring Relays
- Programmable Logic Relays
- Time relays
- Helmholz
- Icotek
- Irinox
- Jean Müller
- NFO Drives
- Katko
- Phoenix Contact
- Rittal
- Rockwell Automation
- Rofag Elektrotechnik AG
- Schneider Electric
- Siemens
- Wago
- Wöhner
- Components
- Enclosures
- Services
- Downloads
3-phase monitoring, adjustable, neutral conductor monitoring
Mains monitoring relay, 3-phase- Multifunctional for monitoring tasks:Undervoltage, overvoltage,Overvoltage and undervoltage ranges, phase failure,Phase sequence, asymmetry, neutral conductor monitoringand voltage fault memory (selectable)- Positive safety logic; opens the normally open contact upon detection of a fault- Controls adjustable from the front withSlotted or Phillips screwdrivers- Colored LED status indicator- Output contact: 1 changeover contact, 6 A, or 2 changeover contacts, 8 A- Cadmium-free contact material- 35 mm wide- For 35 mm mounting rail (EN 60715), power supply monitoring, 3-phase 380–415 V AC, 2 changeover contacts, 8 A, phase failure, phase f 70.42.8.400.2032
Available immediately
Twilight switch
Twilight switch for light-dependentcontrol of lighting systems forpanel installation with separatelight sensor.Type 11.41 - 1 changeover contact, 16 A- European patent, zero-hysteresis principle for energy savings- Italian patent, compensation for the influence of the switched light- 4 selectable functions:- Standard range, switching threshold (1…80) lx- High range, switching threshold (30…1000) lx- Continuous light, helpful during installation, initial testing, and service tasks- Light constantly OFF, suitable for use during vacations- For the first 3 switching cycles (on and off, the delay time was set to zero to simplify installation- LED status indicator- SELV isolation between output contact andpower supply- Double insulation between the light sensor andpower supply- For 35 mm mounting rail (EN 60715)- Cadmium-free contact material- Cadmium-free light sensor (Type 011.02), included in the package twilight switch for in-line installation, up to 1000 lux, 1 changeover contact 16 A, for 230 V AC 11.41.8.230.0000
Available immediately
Twilight switch
Twilight switch for light-dependentcontrol of lighting systems forpanel installation with separatelight sensor.Type 11.31 - 1 NO contact, 16 A- Off-to-on ratio 1.25- Adjustable switching threshold (1…100) lx- Low energy consumption- Version with a supply voltage of(12...24) V AC/DC available- During the first 3 switching cycles (on and off)the delay time has been set to zeroto simplify installation- LED status indicator- SELV isolation between output contact andpower supply- Double insulation between the light sensor andpower supply- For 35 mm mounting rail (EN 60715)- Cadmium-free contact material- Cadmium-free light sensor (Type 011.02), included in the package Twilight switch for in-line installation, 1 to 100 lux, 1 normally open contact, 16 A, for 230 V 11.31.8.230.0000
Available immediately
400 V 3-phase monitoring, 2 W
Mains monitoring relay, 3-phase- Multifunctional for monitoring tasks:Phase sequence and phase failure monitoringeven during reverse voltage- Positive safety logic, opens the normally open contact whenDetection of a fault- Red LED status indicator for phase sequence orPhase failure monitoring- Output contact: 1 changeover contact, 6 A, or 2 changeover contacts, 8 A- Cadmium-free contact material- 17.5 or 22.5 mm wide- For 35 mm mounting rail (EN 60715), power supply monitoring, 3-phase 208–480 V AC, 2 changeover contacts 8 A, phase sequence and phases 70.62.8.400.0000
Available immediately
400 V 3-phase monitoring, 1 W, rail
Mains monitoring relay, 3-phase- Multifunctional for monitoring tasks:Phase sequence and phase failure monitoringeven during reverse voltage- Positive safety logic, opens the normally open contact whenDetection of a fault- Red LED status indicator for phase sequence orPhase failure monitoring- Output contact: 1 changeover contact, 6 A, or 2 changeover contacts, 8 A- Cadmium-free contact material- 17.5 or 22.5 mm wide- For 35 mm mounting rail (EN 60715) Power monitoring for railway applications, 3-phase 208–480 V AC, 1 changeover contact 6 A, Ph 70.61.8.400.0000
Available immediately
Twilight switch
Twilight switch for light-dependent control of lighting systems for distribution board installation with separate light sensor.Type 11.91 - 1 changeover contact 16 A plus oneadditional output for controlling a power module- Timer function for switching off/reducing the light during some night hours to save energy- Additional, light-controlled output- Italian patent, compensation of the influence of the switched light- Adjustable switching threshold (1…150)lx- LCD display for set-up, programming and status- Internal battery (replaceable) for setup,programming, status, power reserve and formaintaining the program in the event of failure of theoperating voltage- Power reserve 5 years- Low stand-by power consumption- SELV isolation between output contact andcontrol- Double insulation between control andlight sensor- For 35 mm mounting rail (EN 60715)- Cadmium-free contact material- Cadmium-free light sensor (Type 011.02), included in the packaging twilight switch and timer, up to 150 lux, 1 changeover contact 16 A + 1 module output, 11.91.8.230.0000
Delivery time on requestk
Level Monitoring Device
Level monitoring relay for conductive liquidsType 72.01- Adjustable sensitivity- Available for 400V AC operating voltage- Also available with an adjustableSensitivity of 5…450 kΩ- Available for low contact loads down to5V / 1mA Positive safety logic during filling and pumping- Monitoring of a level or level range- LED status indicator- Insulation 6 kV - 1.2 / 50μs) between:- Power supply and contacts- Power supply and probes- Contacts and probes- For 35mm mounting rail (EN 60715) Level monitor, for conductive liquids, 1 changeover contact 16 A, adjustable 5 to 72.01.8.240.0002
Available immediately
Level Monitoring Device
Level monitoring relay for conductive liquidsType 72.01- Adjustable sensitivity- Available for 400 V AC operating voltage- Also available with an adjustableSensitivity range of 5…450 kΩ- Available for low contact loads up todown to 5 V / 1 mA- Positive safety logic during filling and pumping- Monitoring of a level or level range- LED status indicator- Insulation 6 kV - 1.2 / 50 μs between:- Power supply and contacts- Power supply and probes- Contacts and probes- For 35 mm mounting rail (EN 60715), level switch for conductive liquids, 1 changeover contact, 16 A, adjustable from 5 to 72.01.8.240.0000
Available immediately
Twilight switch
Twilight switch for light-dependentControl of lighting systems forpanel installation with separateLight sensor.Type 11.31 - 1 NO contact, 16 A- Off-to-on ratio 1.25- Adjustable switching threshold (1…100) lx- Low energy consumption- Version with a supply voltage of(12...24) V AC/DC available- During the first 3 switching cycles (on and off), theDelay time set to zero to simplify installation- LED status indicator- SELV isolation between output contact andPower supply- Double insulation between the light sensor andPower supply- For 35 mm mounting rail (EN 60715)- Cadmium-free contact material- Cadmium-free light sensor (Type 011.02), included in the package; twilight switch for in-line installation, 1 to 100 lux, 1 NO contact, 16 A, for 12–24 11.31.0.024.0000
Available immediately
Single-phase monitoring, adjustable, fault memory
Mains monitoring relays, single- and three-phase- Multifunctional for monitoring tasks:Undervoltage, overvoltage,Overvoltage and undervoltage ranges, phase failure,Phase sequence and voltage fault memory (selectable)- Positive safety logic, opens the normally open contact whenFault Detection- Controls adjustable from the front withSlotted or Phillips screwdrivers- Colored LED status indicator- Output contact: 1 changeover contact, 6 A or 10 A- Cadmium-free contact material- 17.5 or 35 mm wide- For 35 mm mounting rail (EN 60715), mains monitoring, single-phase 220–240 V AC, 1 changeover contact, 10 A, adjustable threshold 70.11.8.230.2022
Available immediately
3-phase monitoring, adjustable, neutral conductor monitoring
Mains monitoring relay, 3-phase- Multifunctional for monitoring tasks:Undervoltage, overvoltage,Overvoltage and undervoltage ranges, phase failure,Phase sequence, asymmetry, neutral conductor monitoringand voltage fault memory (selectable)- Positive safety logic, opens the normally open contact whenfault is detected- Controls adjustable from the front withslotted or Phillips screwdriver- Colored LED status indicator- Output contact: 1 changeover contact 6 A or 2 changeover contacts 8 A- Cadmium-free contact material- 35 mm wide- For 35 mm mounting rail (EN 60715) power supply monitoring, 3-phase 380 - 415 V AC, 1 changeover contact 6 A, phase failure, phase f 70.41.8.400.2030
Available immediately
3-phase monitoring, adjustable, fault memory
Mains monitoring relays, single- and three-phase- Multifunctional for monitoring tasks:Undervoltage, overvoltage,Overvoltage and undervoltage ranges, phase failure,Phase sequence and voltage fault memory (selectable)- Positive safety logic, opens the normally open contact whenFault Detection- Controls adjustable from the front withSlotted or Phillips screwdrivers- Colored LED status indicator- Output contact: 1 changeover contact, 6 A or 10 A- Cadmium-free contact material- 17.5 or 35 mm wide- For 35 mm mounting rail (EN 60715), mains monitoring, 3-phase 380–415 V AC, 1 changeover contact 6 A, phase failure, phase f 70.31.8.400.2022
Available immediately
Monitoring relay Series 7, 1 W, 10 A/250 V AC
3-phase asymmetry 230 VAC (+/-5..+/-20%), adjustable delay time 71.31.8.230.3020
Delivery time on requestk
Monitoring relay Series 71, 1 W, 10 A/250 V AC
Voltage monitoring 400 V AC (+/-5..+/-20%), two adjustable delay times 71.31.8.400.1010
Delivery time on requestk
Thermistor Relay Series 71, Input: 230V AC, 1AK
10A / 250V AC, PTC connection 71.91.8.230.0300
Delivery time on requestk
Pump Changeover Relay
Pump changeover relay 12 ARelay for alternating control of dual installed equipment such as pumps, compressors,heaters or air conditioning unitsType 72.42- Changeover relay- For even wear on the loads- 2 independent normally open outputs rated for 12 A- 2 independent circuits, isolated from the operating voltageControl inputs S1 and S2- Operating voltage 24 or 110…240 V AC/DC- 4 functions- Cadmium-free contact material- 35 mm wide- For 35 mm mounting rail (EN 60715). Relay for alternating switching of 2 loads with 4 functions, 110–240 V
Delivery time on requestk
Thermistor Relay Series 71, Input: 24V AC, 2 W
10 A / 250 V AC, PTC connection 71.92.8.024.0001
Delivery time on requestk
Float Switch
Float switch for heavily contaminated wastewater,Irrigation systems and pump stations72.B1.1.000.xx01- 1 changeover contact- 10 A / 250 V AC, cosφ = 1, 8 A / 250 V AC, cosφ = 0.6- Cable lengths: 5 m, 10 m, 15 m, 20 m- Cable material: polychloroprene- For draining and filling- Contact material: AgNi float switch for pump stations and heavily contaminated water, 1 changeover contact 72.B1.1.000.1001
Delivery time on requestk
Twilight switch
Twilight switch for light-dependentcontrol of lighting systems for thepanel mounting with separate light sensor.Type 11.42 - 1 changeover contact + 1 normally open contact 12 A- Two independent outputs (separately adjustable)- 4 selectable functions:- Standard range, switching threshold (1…80)lx- High range, switching threshold (20…1000)lx- Continuous light, helpful during installation, initial tests and service tasks- Light permanently OFF, suitable for vacation periods- During the first 6 switching cycles (3x ON and 3x OFFper channel) the delay time was set to zero to simplify installation- LED status indicator- SELV isolation between output contact andcontrol- Double insulation between control and light sensor- For 35 mm mounting rail (EN 60715)- Cadmium-free contact material- Cadmium-free light sensor (Type 011.02), included in the package twilight switch for DIN-rail mounting, up to 1000 lux, 1 changeover contact + 1 normally open contact 12 A 11.42.8.230.0000
Delivery time on requestk
Monitoring relay Series 71, 1 W, 10 A/250 V AC
3-phase mains voltage monitoring, 400 V AC 71.31.8.400.2000
Delivery time on requestk
Thermistor Relay Series 71, Input: 24V AC, 1AK
10A / 250V AC, PTC connection 71.91.8.024.0300
Delivery time on requestk
Monitoring relay Series 71, 1 W, 10 A/250 V AC
Single-phase mains voltage monitoring, two fixed delay times, 230 V AC 71.11.8.230.1010
Delivery time on requestk
Monitoring relay Series 7, 1 W, 10 A/250 V AC
3-phase unbalanced 230 VAC (+/-5..+/-20%), adjustable delay time with N connection 71.31.8.230.3022
Delivery time on requestk
Monitoring relay Series 71, 1 W, 10 A/250 V AC
Single-phase mains monitoring 250 VAC (0.75–1.2/fixed) 2 fixed delay times, 230 V AC 71.11.8.230.0010
Delivery time on requestk
Do you have specific requirements?