Single-phase ring-type adjustable transformers RRSP 65-3515 0...230V
Single-phase ring-type transformersRRSP 65 - 3515Single-phase ring-type transformers in economy circuitInput 230 V, output 0–230 VInput 230 V, output 0–260 VInput 230 V, output 0–300 VInput 400 V, output 0–400 VThe RRSP series ring-type transformers comply with national, international, and anticipated future regulations for worldwide use. Configuration:Open design, stationary, for equipment installation and mounting in dry rooms, windings in economy circuit, connection via screw terminals. 3-point front mounting, sizes 65–95 with central mounting.IP 00, up to 2 A insulation class E, above that insulation class B, max. ambient temperature 40°C (ta40°C/B).Versions with separate windings are available upon request.
Delivery time on requestk
REK Dimensions in approx. mm a 48/b 34/c 28/d 58/e 6
Drives and Accessories for Ring-Type Tap-Changing TransformersDrives and Accessories - Motors - Rotary knobs - Scales Configuration:Various motor drives and control systems are available as options for all single- and three-phase ring positioners. Please specify these in plain text when ordering. Please note that the dimensions change for models with a motor and control board. Please contact us directly for these dimensions.Additional options and models available upon request. 0084-00000002
Delivery time on requestk
Single-phase ring-type transformers RRSP 95-3515 0...300 V
Single-phase ring-type transformersRRSP 65 - 3515Single-phase ring-type transformers in economy circuitInput 230 V, output 0–230 VInput 230 V, output 0–260 VInput 230 V, output 0–300 VInput 400 V, output 0–400 VThe RRSP series ring-type transformers comply with national, international, and anticipated future regulations for worldwide use. Configuration:Open design, stationary, for equipment installation and mounting in dry rooms, windings in economy circuit, connection via screw terminals. 3-point front mounting, sizes 65–95 with central mounting.IP 00, up to 2 A insulation class E, above that insulation class B, max. ambient temperature 40°C (ta40°C/B).Versions with separate windings are available upon request.
Delivery time on requestk
REK Dimensions in approx. mm a 38/b 28/c 12/d 41/e 6
Drives and Accessories for Ring-Type Tap-Changing TransformersDrives and Accessories - Motors - Rotary knobs - Scales Configuration:Various motor drives and control systems are available as options for all single- and three-phase ring positioners. Please specify these in plain text when ordering. Please note that the dimensions change for models with a motor and control board. Please contact us directly for these dimensions.Additional options and models available upon request. 0084-00000001
Delivery time on requestk
Single-phase ring-type transformers RRSP 65-3515 0...260 V
Single-phase ring-type transformersRRSP 65 - 3515Single-phase ring-type transformers in economy circuitInput 230 V, output 0–230 VInput 230 V, output 0–260 VInput 230 V, output 0–300 VInput 400 V, output 0–400 VThe RRSP series ring-type transformers comply with national, international, and anticipated future regulations for worldwide use. Configuration:Open design, stationary, for equipment installation and mounting in dry rooms, windings in economy circuit, connection via screw terminals. 3-point front mounting, sizes 65–95 with central mounting.IP 00, up to 2 A insulation class E, above that insulation class B, max. ambient temperature 40°C (ta40°C/B).Versions with separate windings are available upon request.
Delivery time on requestk
RES31-90-100 Diameter 92 mm Scale 0–100%
Drives and Accessories for Ring-Type Tap-Changing TransformersDrives and Accessories - Motors - Rotary knobs - Scales Configuration:Various motor drives and control systems are available as options for all single- and three-phase ring positioners. Please specify these in plain text when ordering. Please note that the dimensions change for models with a motor and control board. Please contact us directly for these dimensions.Additional options and models available upon request. 0085-00000003
Delivery time on requestk
RES31-60-230 Diameter 60 mm Label 0–230 V
Drives and Accessories for Ring-Type Variable TransformersDrives and Accessories - Motors - Rotary knobs - Scales Version:Various motor drives and controls are available as an option for all single-phase and three-phase ring variable transformers. Please specify this clearly when ordering. Attention: for versions with motor and control board, the dimensions change. Please ask us directly for these.Further options and versions on request. 0085-00000002
Delivery time on requestk
RES31-60-100, diameter 60 mm, marked 0–100%
Drives and Accessories for Ring-Type Tap-Changing TransformersDrives and Accessories - Motors - Rotary knobs - Scales Configuration:Various motor drives and control systems are available as options for all single- and three-phase ring positioners. Please specify these in plain text when ordering. Please note that the dimensions change for models with a motor and control board. Please contact us directly for these dimensions.Additional options and models available upon request. 0085-00000001
Delivery time on requestk
REK Dimensions in approx. mm a 76/b 40/c 28/d 90/e 10
Drives and Accessories for Ring-Type Tap-Changing TransformersDrives and Accessories - Motors - Rotary knobs - Scales Configuration:Various motor drives and control systems are available as options for all single- and three-phase ring positioners. Please specify these in plain text when ordering. Please note that the dimensions change for models with a motor and control board. Please contact us directly for these dimensions.Additional options and models available upon request. 0084-00000005
Delivery time on requestk
Single-phase ring-type transformers RRSP 95-3515 0...400 V
Single-phase ring-type transformersRRSP 65 - 3515Single-phase ring-type transformers in economy circuitInput 230 V, output 0–230 VInput 230 V, output 0–260 VInput 230 V, output 0–300 VInput 400 V, output 0–400 VThe RRSP series ring-type transformers comply with national, international, and anticipated future regulations for worldwide use. Configuration:Open design, stationary, for equipment installation and mounting in dry rooms, windings in economy circuit, connection via screw terminals. 3-point front mounting, sizes 65–95 with central mounting.IP 00, up to 2 A insulation class E, above that insulation class B, max. ambient temperature 40°C (ta40°C/B).Versions with separate windings are available upon request.
Delivery time on requestk
RES31-130-100 Diameter 132mm Labeling 0-100%
Drives and Accessories for Ring-Type Tap-Changing TransformersDrives and Accessories - Motors - Rotary knobs - Scales Configuration:Various motor drives and control systems are available as options for all single- and three-phase ring positioners. Please specify these in plain text when ordering. Please note that the dimensions change for models with a motor and control board. Please contact us directly for these dimensions.Additional options and models available upon request. 0085-00000005
Delivery time on requestk
REK Dimensions in approx. mm a 48/b 34/c 28/d 58/e 10
Drives and Accessories for Ring-Type Tap-Changing TransformersDrives and Accessories - Motors - Rotary knobs - Scales Configuration:Various motor drives and control systems are available as options for all single- and three-phase ring positioners. Please specify these in plain text when ordering. Please note that the dimensions change for models with a motor and control board. Please contact us directly for these dimensions.Additional options and models available upon request. 0084-00000003
Delivery time on requestk
Three-Phase Ring-Adjustment Transformers RDRSP 94-3515 450V
Three-Phase Ring-Adjustment TransformersRDRSP 73 - 3515Three-phase ring-tapped transformers in economy circuitInput 3AC 400V, Output 3AC 0–400VInput 3AC 400V, Output 3AC 0–450VInput 3AC 400V, Output 3AC 0–520VThe RRSP series ring-type transformers comply with national, international, and anticipated future regulations for worldwide use. Configuration:Open design, stationary, for device installation and mounting in dry rooms, windings in economy circuit, connection via screw terminals.IP 00, up to 2 A insulation class E, above that insulation class B, max. ambient temperature 40°C (ta40°C/B).Higher currents, other voltages, or versions with separate windings are available upon request.
Delivery time on requestk
Three-Phase Ring-Adjustment Transformers RDRSP 73-3515 400V
Three-Phase Ring-Adjustment TransformersRDRSP 73 - 3515Three-phase ring-tapped transformers in economy circuitInput 3AC 400V, Output 3AC 0–400VInput 3AC 400V, Output 3AC 0–450VInput 3AC 400V, Output 3AC 0–520VThe RRSP series ring-type transformers comply with national, international, and anticipated future regulations for worldwide use. Configuration:Open design, stationary, for device installation and mounting in dry rooms, windings in economy circuit, connection via screw terminals.IP 00, up to 2 A insulation class E, above that insulation class B, max. ambient temperature 40°C (ta40°C/B).Higher currents, other voltages, or versions with separate windings are available upon request.
Delivery time on requestk
REK Dimensions in approx. mm a 76/b 40/c 28/d 90/e 6
Drives and Accessories for Ring-Type Tap-Changing TransformersDrives and Accessories - Motors - Rotary knobs - Scales Configuration:Various motor drives and control systems are available as options for all single- and three-phase ring positioners. Please specify these in plain text when ordering. Please note that the dimensions change for models with a motor and control board. Please contact us directly for these dimensions.Additional options and models available upon request. 0084-00000004
Delivery time on requestk
Three-phase ring-type step-down transformers RDRSP 74-3515 450V
Three-Phase Ring-Adjustment TransformersRDRSP 73 - 3515Three-phase ring-tapped transformers in economy circuitInput 3AC 400V, Output 3AC 0–400VInput 3AC 400V, Output 3AC 0–450VInput 3AC 400V, Output 3AC 0–520VThe RRSP series ring-type transformers comply with national, international, and anticipated future regulations for worldwide use. Configuration:Open design, stationary, for device installation and mounting in dry rooms, windings in economy circuit, connection via screw terminals.IP 00, up to 2 A insulation class E, above that insulation class B, max. ambient temperature 40°C (ta40°C/B).Higher currents, other voltages, or versions with separate windings are available upon request.
Delivery time on requestk
RES31-130-230 Diameter 132 mm scale 0–230 V
Drives and Accessories for Ring-Type Tap-Changing TransformersDrives and Accessories - Motors - Rotary knobs - Scales Configuration:Various motor drives and control systems are available as options for all single- and three-phase ring positioners. Please specify these in plain text when ordering. Please note that the dimensions change for models with a motor and control board. Please contact us directly for these dimensions.Additional options and models available upon request. 0085-00000006
Delivery time on requestk
RES31-90-230, 92 mm diameter, marked 0–230 V
Drives and Accessories for Ring-Type Tap-Changing TransformersDrives and Accessories - Motors - Rotary knobs - Scales Configuration:Various motor drives and control systems are available as options for all single- and three-phase ring positioners. Please specify these in plain text when ordering. Please note that the dimensions change for models with a motor and control board. Please contact us directly for these dimensions.Additional options and models available upon request. 0085-00000004
Delivery time on requestk
Do you have specific requirements?
We’ll provide you with personalized advice and work with you to find the right solution for your application.